X-ray CT solutions for high spatial and temporal resolution!

The TomoScope® software suite is the central platform of interaction with the scanner and offers full control of the scan acquisition process, image reconstruction and image viewing. To enable a seamless workflow it provides an integrated graphical user interface for the wide range of capabilities of the TomoScope® scanners. In addition, direct access to previously acquired scan data, planned and performed image reconstruction data is offered.

Scan Acquisition

• Control of the different scanning options, e.g. single source, dual source (optional), different voltages and exposure times as predefined scan protocols

• Topogram view of the complete object table with graphical planning of the scan range (see Figure 1)

• Overview of the acquisition process and device status display

• Option to plan multiple scans which are then performed automatically

• Integrated data handling to the image reconstruction

Image Reconstruction

• Client-server system with access to the reconstruction server from multiple workplaces for an optimized workflow

• Fast and flexible image reconstruction with preview reconstructions within seconds

• Typical reconstruction times of a volume of 5123 voxels from 720 projections are less than 30 s using GPU hardware (optional)

• Variable voxel and matrix sizes, variable field-of-view

• Wide range of reconstruction kernels from smoothing to edge enhancing

• Export of reconstructed data directly to DICOM, TIFF or ASCII

• Additionally available software modules for retrospectively gated image reconstruction, dual-energy applications and multi-modality image co-registration

Image Viewing

• Integrated viewer for quick evaluation of reconstructed image data

• Advanced viewing and evaluation options with the dedicated viewing software ImpactView

• 2D viewing of volume data (transversal, coronal, sagittal, and 3-pane multi-planar / double-oblique reformatting)

• Slicing, panning, zooming, windowing

• Sliding thin slabs, i.e. either mean / min / max of the pixel data of a ‚slab’ of data

• Threshold-based shaded surface display (surface rendering) of the data

• 2D region-of-interest (ROI) evaluations of rectangular, circular or free-form regions and display of min, mean, max, standard deviation of the voxel values within the region

• Supports DICOM and TomoScope® raw-data formats

• Available for most MS Windows operating systems

 

News

Preclinical Imaging in Small Laboratory Animals, April 22 - 23, 2010

08.03.2010
CT Imaging will present its TomoScope® Synergy Micro-CT scanner at the Workshop "Preclinical Imaging in Small
read more »

 

5th European Molecular Meeting in Warsaw May 26-29, 2010

22.02.2010
CT Imaging will present its TomoScope® Synergy Micro-CT scanner at the 5th Molecular Imaging Meeting that will
read more »

 

Successful Exhibition at RSNA 2009 in Chicago

11.12.2009
CT Imaging presented its new TomoScope® Synergy Twin Micro-CT scanner at the 95th scientific assembly and annual
read more »